Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Southern Medical University ; (12): 884-886, 2009.
Article in Chinese | WPRIM | ID: wpr-268820

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the performance of BNII auto-analyzer system in detecting C3 and C4.</p><p><b>METHODS</b>CLSI protocols (EP15-A, EP6-A, EP9-A2) and other relevant literatures were use to or evaluate the precision, accuracy, linearity of C3 and C4 detection by the auto-analyzer system, and the results were compared with the recognized standards.</p><p><b>RESULTS</b>The relative bias of C3 and C4 was less than one third of the CLIA'88 standard and the precision met the clinical requirement. The results tested by DADE BNII system were not compatible with those by Roche Modular System. C3 showed good linearity in the tests (R2>0.975, P<0.05) with a linearity range of 0.18-5.1 g/L. The linearity of C4 was not available because of lack of high-level samples.</p><p><b>CONCLUSION</b>The performances of DADE BNII System basically meet the recognized standards in clinical detection of C3 and C4, but the method comparison needs further validation.</p>


Subject(s)
Humans , Autoanalysis , Methods , Blood Chemical Analysis , Methods , Complement C3 , Complement C4 , Nephelometry and Turbidimetry , Methods , Proteins , Sensitivity and Specificity
2.
Chinese Journal of Laboratory Medicine ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-685656

ABSTRACT

Objective To establish a method performance verification project and experimental method for the clinical chemiluminescence immunoassay.Methods Referring to CLSI evaluation protocols and pertinent literature,and by combining our actual works,we designed a verification procedure and experimental method.By Using these above,the precision,accuracy,analytical sensitivity,analytical measurement range,clinical reportable range and biotic interval of AFP on the Bayer Centaur 240 chemiluminescence immunoassay system were verificated.Results would be compared with the declaration of the manufacturer or desirable specifications derived from biologic variation.Results The results showed that the between-day inaccuracy on AFP levels at 77.4 ng/ml and 168.0 ng/ml was 5.70% and 4.84% respectively,these were consistent with manufacturer's inaccuracy claimed.The relative bias between the results measured for calibrator at four levels and target value was less 5.0%,and the relative bias between the results measured for EQA control sample at five levels and target value was-3.4% to 11.9%.Lower limit of detection was 1.04 ng/ml,lower slightly manufacturer's analytical sensitivity claimed.Biologic limit of detection was 2.65 ng/ml-3.53 ng/ml,functional sensitivity was 3.53 ng/ml.Analytical measurement range was 3.53-912.00 ng/ml,within manufacturer's liner range claimed.Clinical reportable range was 3.53-182 400.00 ng/ml.Reference interval was 0.6-7.7 ng/ml,within manufacturer' s claimed.Conclusions The main performances of the detection system are accorded with the declaration of the manufacturer.The performance verification procedure and experimental method of our research ars simple and practical,which has important significations for building medical laboratory and laboratory accreditation, improving quality of the chemiluminescence immunoassay.

3.
Chinese Journal of Laboratory Medicine ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-685248

ABSTRACT

Objective To judge method performance of routine biochemistry parameters on Roche Modular PPI testing system by using westgard's method evaluation decision chart.Methods We assessed imprecision(CV)from internal quality control and inaccuracy(bias)from external quality control evaluation.Combined estimates of imprecision and inaccuracy by plotting imprecision as the x-coordinate and inaccuracy as the y-coordinate to locate an expected operating point of every item on the chart.By comparing this operating point with allowable total errors(TEa),we can decide whether the performance is acceptable or not.Results In the 27 different parameters tested,imprecision and bias of calcium were 0.08 mmol/L and 0.06 mmol/L respectively,its performance was marginal.The imprecision of creatinine,urea,glucose, sodium,chloride and phosphorus were 3.20%,2.13%,1.52%,0.89 mmol/L,1.10% and 1.55%,the bias were 4.79%,0.96%,4.63%,0.80 mmol/L,1.74% and 4.13% respectively,their performance was good.M1 other 20 items were of excellence performance.Conclusions Routine biochemistry parameters on Roche Modular PPI testing system possessed good precision and accuracy,and their performance were acceptable.To judge method performance of biochemistry testing system by using westgard' s method evaluation decision chart was easy to do and suited for clinical laboratory.

SELECTION OF CITATIONS
SEARCH DETAIL